Part Winding Reduced Current Types...

Request more information about this product


Series M420 - Combined Manual and Automatic
Series M220 - Manual Non-Automatic

Metron Fire Pump Controllers conform to the latest requirements of Chapter 7, National Fire Protection Association Pamphlet 20, Standard for Centrifugal Fire Pumps, as adopted by Underwriters Laboratories and Factory Mutual. They are withstand rated and listed by Underwriters' Laboratories and approved by Factory Mutual Research Corporation.

Sizes range from 15 to 700 horsepower, 200 to 600 volts, 60 Hz. These controllers are for use on Across-the-Line type installations.

Only the highest quality components, all UL listed or UL recognized are used throughout to assure the best possible reliability. The cabinet is fabricated of heavy gauge reinforced steel with drip-proof hood. All field wiring and service connections may be made from the front, allowing the controller to be mounted flush against a wall.

The controller is completely wired, assembled, and tested at the factory before shipment, and ready for immediate installation.

The series M420 fire pump controllers can be used when full voltage starting may not be desired or practical. The starting contactors operate in sequence to energize a portion of the motor windings on start which reduces inrush current to approximately 65% of normal. An adjustable timing relay is provided to control time between reduced current start and normal running operation. An emergency start lever to close starting contactor independent of automatic control circuits is also supplied as standard. When used, this lever will bypass the reduced current start feature and start the motor with full inrush current drawn from the power source.

The series M220 manual non-automatic controllers contain all of the above standard features except for built-in pressure switch and minimum running period timer, which are omitted. These controllers must be started and stopped via flange-mounted pushbuttons.

Adobe Acrobat PDF Files

Drawings are provided in ADOBE pdf Format and are provided for reference only. Drawings and Specifications subject to change without notice. Drawings should not be used for construction. Contact our sales department for specific as-built drawings for your special project.

Download Operations Manuals (PDF)
Operations Manuals M300-420 - English
Operations Manuals M300-420 - Spanish

Specifications:
Bulletin - M420-M220 Part Winding Reduced Current

Enclosure Dimensions:
M420 Enclosure Dimension Drawing, 28" X 54" Cabinet
M420 Enclosure Dimension Drawing, 32" X 59" Cabinet
M420 Enclosure Dimension Drawing, 43" X 68" Cabinet
M420 Enclosure Dimension Drawing, 43" X 84" Cabinet

Hookup Drawings:
M420 External Hookup Drawing, For Use With Dwg CD32913, CD32916
M420 External Hookup Drawing, For Use With Dwg CD32944, CD32950

Schematics:
M420 Schematic Drawing

Enclosure Dimensions w/Transfer Switch:
M420 W/Xsfer Switch Enclosure Dimension Drawing, 56" X 54" Cabinet
M420 W/Xsfer Switch Enclosure Dimension Drawing, 64" X 59" Cabinet
M420 W/Xsfer Switch Enclosure Dimension Drawing, 97" X 68" Cabinet
M420 W/Xsfer Switch Enclosure Dimension Drawing, 108" X 84" Cabinet

Hookup Drawings w/Transfer Switch:
M420 W/Xsfer Switch External Hookup Drawing, For Use With Dwg CD32929, CD32932
M420 W/Xsfer Switch External Hookup Drawing, For Use With Dwg CD32956, CD32962

Schematics w/Transfer Switch:
M420 W/Xsfer Switch Schematic Drawing