Jockey Pump Controllers

 

 
 
  

 The M15 Jockey (or make-up) Pump Controllers are in the same system as the main fire pump controller(s). Their purpose is to maintain normal water pressure and to help prevent unnecessary cycling of the main fire pump(s).

 

The M15 series Jockey Pump Controllers are listed to UL 508 Standard for Industrial Controls. Each controller contains an externally operable horsepower rated motor circuit protection device, a motor contactor and a door mounted hand-off-auto switch all housed in a NEMA 2 drip proof enclosure. 

 

The M15A and M15B Jockey Pump Controllers include a 6-230 psi pressure switch with independent high and low set points for automatic starting and stopping. The pressure switch is piped to an external 1/4" NPT connector.

 

The M15A incorporates a control power transformer and run period timer.

 

The M15B omits the run period timer and the control power transformer.

 

Standard features of the M15A:

  • Externally operable motor starter protector

  • Hand-off-auto selector switch

  • 6-230 psi pressure switch

  • Control power transformer

  • Minimum run period timer

  • NEMA 2 Enclosure

 

                                                                                                                      


Download Operations Manuals (PDF)
Operations Manuals M15 - English
Operations Manuals M15 - Spanish
Alco Pressure Switch Setup - English
Alco Pressure Switch Setup - Spanish

Specifications:
Bulletin - M15 Series Jockey Pump Controller

Schematics:
M15A Schematic Drawing - 3 Phase
M15A Schematic Drawing - 1 Phase
M15B Schematic Drawing - 3 Phase
M15B Schematic Drawing - 1 Phase


Enclosure Dimensions:
Model M15A - Enclosure Dimension Drawing, Std. Cabinet, Nema 2,3R
Model M15A Enclosure Dimension Drawing, Large Cabinet, Nema 2,3R
Model M15A Enclosure Dimension Drawing, Std. Cabinet, Nema 4,4X, 12
Model M15A Enclosure Dimension Drawing, Large Cabinet, Nema 4,4X, 12
Model M15B Enclosure Dimension Drawing, Std. Cabinet, Nema 2,3R
Model M15B Enclosure Dimension Drawing, Large Cabinet, Nema 2,3R
Model M15B Enclosure Dimension Drawing, Std. Cabinet, Nema 4,4X, 12
Model M15B Enclosure Dimension Drawing, Large Cabinet, Nema 4, 4X,12

 

Drawings are provided in Adobe pdf Format and are provided for reference only. Drawings and Specifications subject to change without notice. Drawings should not be used for construction. Contact our sales department for specific as-built drawings for your special project.